Required practical 1: Rate of an enzyme-controlled reaction

This guide covers required practical 1, measuring how one variable changes the rate of an enzyme-controlled reaction. It takes you through the method, the variables to control and the denatured enzyme control. Worked examples show rate, initial rate and percentage uncertainty.

  • Level AS and A-level
  • Specification 3.1.4.2
  • Practical skills AT a, b, c, f, l
  • Price Free

Aim

Find out how one chosen variable changes how fast an enzyme works. You choose the variable: temperature, pH, enzyme concentration, substrate concentration or inhibitor concentration.

This guide uses amylase, starch and temperature as its example. The same plan works for other enzymes and variables.

Apparatus

  • Amylase solution and starch solution, each of known concentration. Typical values: 1% starch and 1% amylase.
  • Buffer solution, to keep the pH constant. For example pH 7.
  • Iodine solution and a tile for test drops
  • Water baths and a thermometer. Typical range: 20 °C to 60 °C.
  • Syringes or pipettes to measure volumes, and a stopwatch
  • Boiled (denatured) amylase, for the control
  • Test tubes and a rack, droppers and eye protection

A typical method (your school's may differ slightly)

  1. Put one drop of iodine solution into each well of the tile before you start. You may need more than one tile.
  2. Choose at least five temperatures, and set a water bath to each one. For example, use 20, 30, 40, 50 and 60 °C.
  3. Measure the same volume of starch solution and of buffer into one tube, and the same volume of amylase solution into another. Typical volumes are 5 cm³ of starch, 1 cm³ of buffer and 2 cm³ of amylase.
  4. Stand both tubes in the water bath and wait until the solutions reach its temperature before you mix them. About 5 minutes is usually enough. Check with a thermometer.
  5. Mix the two solutions and start the stopwatch.
  6. At regular short intervals, for example every 10 seconds, add a drop of the mixture to a fresh drop of iodine solution. Use a clean dropper for each tube. Keep the mixture in the water bath throughout.
  7. Record the time when the iodine solution first stays orange-brown. No starch is detected at this point. If the iodine is still blue-black after 10 minutes, stop and record that starch was still present. You cannot calculate a rate from 1 ÷ time for this tube.
  8. Repeat at least three times at each temperature and calculate a mean time.
  9. Run the control described below at each temperature. To make denatured amylase, boil the solution for about 5 minutes, then cool it.

Variables and controls

  • Independent variable: The one variable you change, here temperature.
  • Dependent variable: Time taken for the starch to be hydrolysed, which is used to calculate a rate.
  • Control variables:
    • Concentration and volume of the starch solution
    • Concentration and volume of the amylase solution
    • pH, using a buffer
    • Concentration of the iodine solution, and the volume of each test drop
    • Temperature, using a water bath kept below the optimum, whenever temperature is not the variable being tested

Controls

  • Use the same volume of buffer and the same concentration of starch, but with denatured (boiled) amylase at the same concentration. This shows that the active enzyme causes the change.
  • If you add an inhibitor, also run a mixture with the same volume of water in place of the inhibitor solution.

Risks

Do this practical only as your teacher instructs, following their risk assessment.

  • Hot water and boiling amylase can scald: use a tube holder, keep equipment away from the bench edge, and take care above 50 °C.
  • Iodine solution stains and can irritate eyes: wear eye protection and wipe up spills.
  • Enzymes can irritate skin and eyes or cause an allergic reaction: avoid contact, do not make dust from powder, and wash off splashes.
  • Follow your teacher's risk assessment for the water baths and solutions you use.

Processing the results

MS codes are the maths skills in the specification.

  • Put the independent variable in the left-hand column of the results table. Units go only in the headings, with one time unit throughout and each mean to the number of decimal places asked for. MS 0.1, MS 0.2
  • Turn each mean time into a rate: rate = 1 ÷ time, or 1000 ÷ time for easier numbers. MS 0.1

    Example: A mean time of 125 s gives 1 ÷ 125 = 0.0080 s⁻¹, or 1000 ÷ 125 = 8.0 on the easier scale.

  • Plot temperature (a continuous variable) on the x-axis and rate on the y-axis, as a line graph. MS 3.2
  • If you measured product over time instead, draw a tangent to the curve at time zero. Its gradient is the initial rate. MS 3.6

    Example: A tangent that rises by 12 cm³ in 40 s gives an initial rate of 12 ÷ 40 = 0.30 cm³ s⁻¹.

  • The time you record is uncertain because you only test at intervals. Percentage uncertainty = interval ÷ time × 100. MS 1.11, MS 0.3

    Example: Testing every 10 s with an end point at 80 s: 10 ÷ 80 × 100 = 12.5%. Testing more often lowers it.

  • An optimum read from results 10 °C apart could lie anywhere between the neighbouring temperatures. Test smaller intervals around the fastest rate.

Common mistakes and how marks are lost

  • Writing "same pH" and stopping there. Say that a buffer keeps the pH constant.
  • Leaving out a denatured enzyme control, or changing the independent variable in the control.
  • In a pH investigation, running a control at a temperature that would itself denature the enzyme.
  • Giving enzyme concentration as the independent variable on a graph of substrate or product concentration against time. There, time is the independent variable.
  • Reading a longer time as a faster reaction.
  • Mixing units in a table, not converting times to a single unit, or giving means to the wrong number of decimal places.
  • On a graph of rate against substrate concentration, explaining the plateau as the reaction stopping. It means that all the active sites are occupied, or enzyme concentration is limiting.
  • Explaining a faster rate without saying that more enzyme-substrate complexes form.
  • Writing that an enzyme "worked well" instead of stating its activity.
  • Misreading a fall in substrate concentration. It means that substrate has been used up in the reaction.
  • Naming a substrate that was not varied as the limiting factor.
  • Giving temperature when asked what a control tube should contain.
  • Changing the inhibitor concentration to confirm competitive inhibition. Change the substrate concentration instead.

Related free topic banks

Related revision notes

Written by Helicate for AQA AS and A-level Biology. Not an official AQA resource. Free for personal study and for use in your own school or college; please don't resell or re-host it.

Spotted something wrong? Report a mistake in this guide.

All practical guides