Required practical 8: Dehydrogenase activity in chloroplast extracts

This guide covers required practical 8, measuring dehydrogenase activity in extracts of chloroplasts. It explains how the extract is made, how a redox indicator shows the activity and what each control shows. Worked examples cover rate and light intensity.

  • Level A-level only (not in the AS course)
  • Specification 3.5.1
  • Practical skills AT a, b, c
  • Price Free

Aim

Find out how one chosen factor, such as light intensity, affects the rate of dehydrogenase activity in chloroplast extracts.

A redox indicator shows the activity. In the light, electrons released from chlorophyll are accepted by the indicator instead of NADP, so the indicator is reduced and changes colour.

Apparatus

  • Leaves, and a cold, buffered solution with the same water potential as the chloroplasts. Spinach is typical, with 0.4 mol dm⁻³ sucrose in pH 7 buffer.
  • Equipment to break open the cells and to filter, and a centrifuge. For example scissors, a chilled pestle and mortar or blender, muslin, a funnel and an ice bath.
  • Redox indicator. For example DCPIP, which is blue when oxidised and colourless when reduced.
  • Lamp and ruler
  • Reference tube showing the end point, or a colorimeter
  • Tubes, pipettes or syringes, and a stopwatch
  • Water bath at 20 °C, thermometer, beaker of water as a heat shield, boiling water bath and aluminium foil

A typical method (your school's may differ slightly)

  1. Break open leaf cells in a cold, buffered solution that has the same water potential as the chloroplasts. Cold slows enzyme activity, the buffer stops enzymes denaturing, and the equal water potential prevents osmosis damaging the chloroplasts. Filter to remove debris and intact cells. For example, remove the stalks and midribs from about 10 g of leaf, use about 20 cm³ of ice-cold solution, and filter through several layers of muslin into a tube on ice.
  2. Centrifuge to remove nuclei and debris. Then spin the remaining liquid faster, so that the chloroplasts settle out. Mix the chloroplasts with fresh cold, buffered solution to make the extract. Use a slow spin of about 2 minutes first, then a faster spin of about 10 minutes. Pour off the liquid from the faster spin, and add about 5 cm³ of the fresh solution. Keep the extract on ice and in dim light.
  3. Work in a dim room. Keep the tubes at 20 °C, with a beaker of water between lamp and tube to absorb heat.
  4. Place a tube of chloroplast extract at a measured distance from the lamp. Typical volumes are 0.5 cm³ of extract and 5 cm³ of indicator made up in the buffered solution. Distances of 10 cm to 50 cm are typical.
  5. Add the redox indicator and start the stopwatch.
  6. Record the time taken for the colour to match the reference tube. A colorimeter makes the end point less subjective: time how long the absorbance takes to reach a set value. The reference tube holds the same volume of extract with buffered solution in place of the indicator. If you use a colorimeter, use a red filter and zero it with that tube.
  7. Repeat at each distance and calculate a mean time. Three or more repeats are typical.
  8. Repeat the whole procedure at other distances, and set up the two controls below.
  9. For the dark control, wrap the tube in foil. For the heated control, put a tube of extract in a boiling water bath for about 5 minutes, then cool it. Leave each for as long as the slowest tube took.

Variables and controls

  • Independent variable: Light intensity, changed by moving the lamp.
  • Dependent variable: Time for the indicator to change colour, used to calculate a rate.
  • Control variables:
    • Concentration of the redox indicator
    • Quantity of chloroplasts, and so of chlorophyll and dehydrogenase, in each tube
    • Temperature

Controls

  • Extract and indicator kept in the dark: shows that light is needed for the indicator to change colour.
  • Heated extract and indicator in the light: heating denatures the enzymes, so this shows that the colour change needs active enzymes.

Risks

Do this practical only as your teacher instructs, following their risk assessment.

  • Centrifuge: balance the tubes in opposite holders, keep the lid closed, and wait until it stops.
  • Boiling water can scald: wear eye protection and use a tube holder.
  • The lamp gets hot and water conducts electricity: do not touch the bulb, keep water away from sockets, and use dry hands.
  • The indicator stains and can irritate: wear eye protection and gloves.
  • Blender and scissor blades are sharp: unplug a blender before touching it.
  • Follow your teacher's risk assessment for the centrifuge, the lamp and the indicator.

Processing the results

MS codes are the maths skills in the specification.

  • Calculate a mean time, then rate = 1 ÷ time. A shorter time means a faster rate, so the ratio of two rates is the ratio of their times turned upside down. MS 1.2, MS 0.1, MS 0.3

    Example: Times of 240 s and 160 s: the second rate is 240 ÷ 160 = 1.5 times the first.

  • Light intensity is proportional to 1 ÷ distance². To compare two distances, divide the larger by the smaller and square the answer. MS 0.3, MS 2.3

    Example: Moving the lamp from 30 cm to 10 cm: (30 ÷ 10)² = 9 times the light intensity.

  • Plot light intensity (x-axis) against rate (y-axis). MS 3.2
  • Where the rate stops rising as light intensity rises, another factor is limiting, such as the indicator concentration, the number of chloroplasts or the temperature.

Common mistakes and how marks are lost

  • Saying that the indicator is oxidised. It is reduced.
  • Using the ratio of the distances as the ratio of the light intensities. Square it.
  • Giving the rate ratio upside down, by forgetting that a longer time is a slower rate.
  • Giving the percentage increase in time when asked for the percentage decrease in rate.
  • Writing reduced NAD or NADH in place of reduced NADP.
  • Saying that a solution with the same water potential protects cells. It protects organelles, by preventing osmosis into or out of them.
  • Saying a buffer stops organelles denaturing. It stops enzymes or other proteins denaturing.

Related free topic banks

Written by Helicate for AQA A-level Biology. Not an official AQA resource. Free for personal study and for use in your own school or college; please don't resell or re-host it.

Spotted something wrong? Report a mistake in this guide.