Required practical 6: Antimicrobial substances and aseptic technique

This guide covers required practical 6, using aseptic technique to test antimicrobial substances. It sets out each aseptic step, both controls and how to process clear zones. Worked examples cover area, dilutions and percentage uncertainty.

  • Level AS and A-level
  • Specification 3.4.4
  • Practical skills AT c, i
  • Price Free

Aim

Use aseptic technique to find out how antimicrobial substances affect the growth of microorganisms.

Apparatus

  • Liquid culture of bacteria and agar plates. Use a safe school strain, such as a non-pathogenic Escherichia coli.
  • Sterile pipette or syringe, and a sterile spreader
  • Bunsen burner
  • Soap and disinfectant
  • Antimicrobial substances and sterile water. For example mouthwash, or antiseptic at 0, 25, 50, 75 and 100%.
  • Paper discs and sterile forceps. Discs about 6 mm in diameter are typical.
  • Ruler
  • Marker pen, adhesive tape, incubator and eye protection

A typical method (your school's may differ slightly)

  1. Label the base of each plate with the date, the bacterium and the position of each disc.
  2. Wash your hands with soap and disinfect the bench.
  3. Work close to a lit Bunsen burner, where rising air carries contaminants away.
  4. Open the culture bottle and flame its neck before and after you take the culture. Replace the bottle lid immediately.
  5. Use a sterile pipette to transfer a measured volume of culture to the agar. Lift the lid of the plate only slightly, at an angle. A typical volume is 0.1 cm³.
  6. Spread the culture with a sterile spreader. Move it over the whole surface, then let the liquid soak in for a few minutes with the lid on.
  7. Put the pipette and the spreader into disinfectant straight after use.
  8. If you test a range of concentrations, record the volumes of antimicrobial substance and water used to make each one.
  9. With sterile forceps, place a paper disc carrying each substance on the agar. Include the two controls below. Soak the discs for the same time and let excess liquid drain off. Space them well apart, and press each one down gently with the forceps.
  10. Hold the lid on with two or more short strips of tape. Do not seal all the way round, so that air can enter. Turn the plate upside down, so that condensation does not drip onto the agar.
  11. Incubate all the plates at the same temperature for the same time. In schools this is typically 25 °C for 24 to 48 hours.
  12. Measure the diameter of the clear zone round each disc. Measure through the closed plate, without opening it. Take two diameters at right angles and find the mean.
  13. Repeat with at least three plates for each treatment and calculate a mean.

Variables and controls

  • Independent variable: Type or concentration of the antimicrobial substance.
  • Dependent variable: Diameter or area of the clear zone.
  • Control variables:
    • Species of bacterium, and volume of culture spread on each plate
    • Diameter of the paper discs
    • Temperature and time of incubation

Controls

  • Negative control: sterile water, or the solvent without the test substance.
  • Positive control: a substance already known to be antimicrobial, such as an antibiotic, antiseptic or disinfectant.

Risks

Do this practical only as your teacher instructs, following their risk assessment.

  • Bacteria getting out of the dish: lift the lid only slightly, at an angle.
  • Bacteria reaching the bench: put each used pipette or spreader straight into disinfectant.
  • Other microorganisms getting into the culture: use sterile equipment, flame the neck of the bottle and work near the Bunsen burner.
  • Harmful bacteria could grow: do not incubate near body temperature, do not seal the plate completely, and never open it after incubation.
  • Used plates: hand them in unopened, for staff to sterilise in an autoclave or pressure cooker before disposal.
  • Spilled culture: tell your teacher at once, so that it can be covered with disinfectant.
  • Bunsen flame: tie back hair and loose clothing, and turn it to the yellow flame when not in use.
  • Alcohol or alcohol-based disinfectant is flammable: keep it well away from the flame.
  • Wash your hands with soap at the end, cover cuts, and do not eat or drink.
  • Follow your teacher's risk assessment for the flame, and for incubating and disposing of the plates.

Processing the results

MS codes are the maths skills in the specification.

  • Calculate the mean or median diameter for each treatment. MS 1.2, MS 1.6
  • Area of a circle = πr². Halve the diameter first. To find only the clear area around a disc, subtract the area of the disc. MS 4.1

    Example: Zone 26 mm and disc 6 mm in diameter: π(13² − 3²) = 503 mm² (3 significant figures).

  • If you count colonies instead: number in the undiluted culture = number of colonies × dilution factor ÷ volume spread. Use standard form. MS 0.2, MS 0.3

    Example: 42 colonies from 0.1 cm³ of a 10⁻⁴ dilution (dilution factor 10⁴): 42 × 10⁴ ÷ 0.1 = 4.2 × 10⁶ cells per cm³.

  • Show different substances (separate categories) on a bar chart with labelled axes. MS 1.3, MS 3.2
  • Compare the ranges given by mean ± 2 standard deviations. If they overlap, the difference is likely to be due to chance. MS 1.10
  • Percentage uncertainty of a volume = uncertainty ÷ volume measured × 100. MS 1.11, MS 0.3

    Example: ±0.02 cm³ on 0.50 cm³: 0.02 ÷ 0.50 × 100 = 4%.

  • Limit your conclusion. A test on one species, in a laboratory, at one temperature may not apply elsewhere.

Common mistakes and how marks are lost

  • Offering gloves, closed windows, flaming the lid or plate, or "sterilise all equipment" as aseptic steps. None earns credit.
  • Writing "sterilise hands" or "sterilise surfaces". Wash hands with soap, or disinfect the bench.
  • Using a loop to transfer or spread a set volume. Transfer it with a sterile pipette or syringe.
  • Saying that air movement sterilises the air. It carries contaminants away.
  • Writing "work quickly with the lid off". Lift the lid only slightly.
  • Giving a ratio when asked for the volumes used to make a dilution.
  • Comparing clear zone diameters when asked to compare the width of clear agar beyond the disc.
  • Repeating aseptic steps that the question has already given, or explaining when asked only to describe.
  • Swapping the positive and negative controls, or leaving the negative control with nothing added. Use sterile water or the solvent alone.
  • Describing contamination as a chemical. It means other microorganisms.
  • Saying the results are significant or due to chance. Refer to the difference.
  • Using 1 standard deviation when the comparison needs 2.
  • Leaving out part of the dilution factor when working back to the undiluted culture.
  • Drawing a histogram instead of a bar chart, or leaving axes unlabelled.
  • Saying that bacteria become immune, or that an antibiotic causes a mutation.

Related free topic banks

Written by Helicate for AQA AS and A-level Biology. Not an official AQA resource. Free for personal study and for use in your own school or college; please don't resell or re-host it.

Spotted something wrong? Report a mistake in this guide.

All practical guides