Required practical 4: Permeability of cell-surface membranes
This guide covers required practical 4, using beetroot to find out how temperature affects membrane permeability. It explains the method, the control variables and how to interpret an absorbance curve. Common mistakes show how marks are lost.
- Level AS and A-level
- Specification 3.2.3
- Practical skills AT a, b, c, j, l
- Price Free
Aim
Find out how one chosen variable, such as temperature or ethanol concentration, changes the permeability of cell-surface membranes.
This guide uses beetroot and temperature. Beetroot cells contain a coloured pigment. The more permeable the membranes become, the more pigment leaks out.
Apparatus
- Beetroot, cork borer, scalpel and ruler
- Distilled water and paper towel
- Tubes, and syringes or pipettes to measure volumes
- Water baths and a thermometer
- Colorimeter, or a set of colour standards of known pigment concentration
- Stopwatch
- Tile, forceps, boiling tubes and a rack, cuvettes, eye protection, and ethanol if you test it
A typical method (your school's may differ slightly)
- Cut beetroot discs of the same diameter and thickness with a cork borer, ruler and scalpel. For example, 8 mm in diameter and 2 mm thick.
- Rinse the discs in distilled water and blot them dry. This removes pigment released from cells that were cut. Rinse until the water stays clear.
- Let tubes holding the same volume of distilled water reach each temperature. Try a wide range first, such as 20 °C to 80 °C in 10 °C steps. A typical volume is 10 cm³.
- Add the same number of discs to each tube and leave them for the same time, for example 20 minutes. Five discs in each tube is typical.
- Check the temperature at intervals with a thermometer, and adjust the water bath if it changes.
- Remove the discs and mix each solution. Remove them gently, without squeezing.
- Zero the colorimeter with distilled water, then measure the absorbance of each solution using the same filter. A green filter (about 530 nm) suits the red pigment. Use a clean cuvette filled to the same level.
- Repeat at least three times at each temperature and calculate a mean.
- Run it again with small intervals, such as 2 °C, around the temperature where absorbance starts to rise.
- To test ethanol instead, use concentrations such as 0% to 70% in steps of 10%, in covered tubes at about 20 °C, for the same time, and zero the colorimeter with the matching ethanol solution.
Variables and controls
- Independent variable: The one variable you change, here temperature.
- Dependent variable: Absorbance of the solution, which shows how much pigment has been released.
- Control variables:
- Diameter and thickness (or mass, or surface area) of the discs, and the number of discs
- Volume of water, because it affects the concentration of the pigment
- Time in the water
- Temperature, monitored and corrected, whenever it is not the variable being tested
- Colorimeter filter
Controls
- If ethanol concentration is the variable, include 0% ethanol.
- If freezing is the treatment, include tissue kept cold but not frozen, for example at 4 °C. Without it, low temperature alone could explain the damage.
- For the temperature version, discs kept in water at about 20 °C show how much pigment is released without heating.
Risks
Do this practical only as your teacher instructs, following their risk assessment.
- Cutting tissue: use a sharp blade, cut away from your body on a hard surface, and carry the blade covered or pointing down.
- Cork borer: push it down into the beetroot on a tile, never towards your hand.
- Hot water can scald: use a tube holder, and take extra care at 60 °C or above.
- Ethanol is highly flammable and harmful: wear eye protection and keep it away from naked flames. Never heat it with a flame.
- Acid can irritate skin and eyes: wear eye protection and rinse off splashes.
- Follow your teacher's risk assessment for hot water, ethanol and acid.
Processing the results
MS codes are the maths skills in the specification.
- Calculate the mean absorbance at each value of the variable.
- Plot mean absorbance (y-axis) against temperature (x-axis) and find where the absorbance starts to rise sharply.
- To turn absorbance into pigment concentration, make a dilution series of known pigment concentrations, plot absorbance against concentration as a calibration curve, and read off the value for your sample.
- With no colorimeter, make a dilution series of known pigment concentrations and compare your solution with these colour standards.
- The uncertainty of a reading from a scale is half of one division. Use an instrument with finer graduations to reduce it.
Example: A scale marked every 5 cm³ reads to ±2.5 cm³. For 50 cm³ the percentage uncertainty is 2.5 ÷ 50 × 100 = 5.0%.
- Interpret the curve. Ethanol dissolves phospholipids. Acid or high temperature denatures membrane proteins, and high temperature also makes the membrane more fluid. The curve levels off once the membranes are fully permeable.
Common mistakes and how marks are lost
- Treating the practical as osmosis and writing about water potential.
- Naming the cell wall. The cell-surface membrane is the barrier to the pigment.
- Saying high temperature denatures "enzymes". It denatures membrane proteins.
- Not being able to say why ethanol or acid damages the membrane.
- Giving generic control variables such as pH, "concentration of solutions" or "fair test".
- Writing "amount" for volume, or "size" or "shape" for the dimensions of the discs.
- Assuming the water bath stays at one temperature. Say how you check it and what you do if it changes.
- Not halving the scale division when stating an uncertainty, or suggesting "higher resolution" to reduce it.
- Proposing a colorimeter when none is available.
Related free topic banks
- Transport across cell membranes 3.2.3: Has a section on required practical 4.
Written by Helicate for AQA AS and A-level Biology. Not an official AQA resource. Free for personal study and for use in your own school or college; please don't resell or re-host it.
Spotted something wrong? Report a mistake in this guide.